Identification of Gram-Negative Pathogenic Bacteria in Microbiology Practical Equipment at the Central Laboratory of Stikes Maharani, Malang

Authors

  • Nurhasanah Nurhasanah Prodi Teknologi Laboratorium Medis, STIKes Maharani Malang, Malang, 65143, Indonesia
  • Mahtuti Mahtuti Prodi Teknologi Laboratorium Medis, STIKes Maharani Malang, Malang, 65143, Indonesia
  • Husnah Husnah Prodi Teknologi Laboratorium Medis, STIKes Maharani Malang, Malang, 65143, Indonesia

DOI:

https://doi.org/10.57174/j.born.v4i2.144

Keywords:

biochemical tests, identification, laboratory equipment, microbiology

Abstract

Stacks of laboratory equipment and lack of routine sterilization can contribute to the growth and contamination of pathogenic bacteria. This research aimed to determine the types of gram-negative pathogenic bacteria present in the microbiology practicum equipment at the Central STIKes Maharani Malang Laboratory. This type of research is descriptive research with an analytical research design. The sampling technique uses purposive sampling. This research involves taking swab samples on the surface of practical microbiology equipment, isolating bacterial colonies using MCA (Mac Conkey Agar) media, making pure cultures on MCA slanted agar media, macroscopic observations, and biochemical tests. Bacteria were grown on MCA media for 2x24 hours. The results of research using gram staining showed gram-negative bacteria, rod-shaped, spread, and red. Biochemical tests showed glucose (+g), lactose (+), mannitol (+), maltose (+), sucrose (+), H2S (-), indole (-), Mr (Methyl Red) (-), Vp ( Voges Praskaeur) (+), citrate (+), motility (-), the bacterial species Klebsiella pneumoniae was found. The second result shows glucose (+g), lactose (+), mannitol (+), maltose (+), sucrose (+), H2S (-), indole (+), Mr (Methyl Red) (+), Vp ( Voges Praskaeur) (-), citrate (-), motility (-), found Escherichia coli bacterial species. This study concluded that it was found that gram-negative bacteria were rod-shaped, spread, and red. Meanwhile, from biochemical tests using glucose, lactose, mannitol, maltose, sucrose, ındol, MR, VP, and citrate, Klebsiella pneumoniae and Escherichia coli bacteria were found.

Downloads

Download data is not yet available.

References

1. Sanjaya ZW. Gambaran Bakterı Gram Negatıf pada Lımbah Caır Laboratorıum Klınık Stıkes Maharanı Malang. 2023. 8–65 hlm.

2. Rahmah WN, Sartika F, Madureni YES. Identıfıkası Bakterı Pada Nutrıent Agar Plate Palangka Raya Identification Of Bacteria On Nutrient Agar Plate At The Universitas Muhammadiyah Palangkaraya ’ s Microbiology Laboratory. Borneo J Med Lab Technol BJMLT. 2023;5:338–43.

3. Putri PKPD, Yustiantara IPS. Review: Efektivitas Sterilisasi Dengan Ozon (O3) Pada Peralatan Laboratorium Sebagai Upaya Penjaminan Kualitas Dan Mutu. J Sci Mandalıka JSM E-ISSN 2745-5955 P-ISSN 2809-0543. 2023;4(5):62–70.

4. Labunda AI, Fatayati I, Slamet. Identıfıkası bakterı Klebsıella pneumonıa pada Swab Luka Dıabetes Mellıtus dı Klınık Perawatan Luka Kota Pontıanak. Malahayatı Health Stud J. 2024;4(2):598–604.

5. Kartikasari AM, Hamid IS, Elziyad MT, Damayanti R, Fikri F, Praja RN. Isolasi dan Identifikasi Bakteri Escherichia coli Kontaminan Pada Daging Ayam Broiler Di Rumah Potong Ayam Kabupaten Lamongan. J Med Vet. 2019;2(1):66–71.

6. Dorawati M, Herawati I, Fauziah PN. Identifikasi Bakteri Gram Negatif dari Sputum Penderita Infeksi Saluran Pernapasan Akut di Rumah Sakit Dustira Kota Cimahi. J Ilm Anal Kesehat. 2021;7(1):37–44.

7. Konoralma K. Identifikasi Bakteri Penyebab Infeksi Nosokomial di Rumah Sakit Umum Gmim Pancaran Kasih Manado. J Kesmas. 2019;8(1):23–35.

Published

31-07-2024

How to Cite

1.
Identification of Gram-Negative Pathogenic Bacteria in Microbiology Practical Equipment at the Central Laboratory of Stikes Maharani, Malang. JB [Internet]. 2024 Jul. 31 [cited 2025 Apr. 23];4(2):67-80. Available from: https://journalborneo.com/index.php/jb/article/view/144

Similar Articles

1-10 of 28

You may also start an advanced similarity search for this article.